Luminescent "EXIT" Panoramic Sign 210 x 210mm COFAN

Brand:

Luminescent "EXIT" Panoramic Sign 210 x 210mm COFAN

Read moreShow less
€18.16
€18.16 (TAX incl.)
€15.01 (no TAX)
Measurements
Solicitar más información
<h3 style="text-align: center; margin-bottom: 25px;">Solicitud de información de este producto</h3>

What can I help you?

Reference:
CFPAN01LU210210

SHIPMENTS

from 3,99€ + VAT. Free from €150 +VAT

EXCHANGES AND RETURNS

Free up to 14 days after purchase, excluding personalized and made-to-order products

EXCHANGES AND RETURNS

WE HELP YOU

+34 876 43 01 24
[email protected]

You may also like
No items
Description

COFAN luminescent "EXIT" Panoramic Sign 210 x 210mm. High quality and easy installation emergency sign. The sign is used to mark buildings, auditoriums, companies and factories to indicate spaces intended for exit or evacuation

The poster is made with a layer of photoluminescent pigment (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).

PRODUCT IDENTIFICATION

According to UNE 23035/4 standard:

  • Name or brand of the manufacturer
  • Manufacturing date
  • Designation (class A or class B as appropriate)

According to RIPCI 513:

  • Name or brand of the manufacturer

MINIMUM LUMINESCENCE VALUES AFTER SALT CHAMBER

All NMZ signage is subjected to different internal and external light response tests that guarantee compliance with the light intensity values contemplated in the UNE 23035 standard.

A CLASS:

Time Values of UNE 23035-4 (2003)
A CLASS
ValuesSekureco
A CLASS
Luminescence 10 minutes 210 mcd/m2 225 mcd/m2
Luminescence 60 minutes 29 mcd/m2 30 mcd/m2
Dimming time: 3,000 minutes 3,100 minutes

CLASS B:

Time Values of UNE 23035-4 (2003)
A CLASS
ValuesSekureco
A CLASS
Luminescence 10 minutes 40 mcd/m2 50 mcd/m2
Luminescence 60 minutes 5.6 mcd/m2 6.1 mcd/m2
Dimming time: 800 minutes 900 minutes

CHARACTERISTICS

PVC SUPPORT MATERIALS

According to UNE 53127 standard:

  • White PVC 1mm for class A and transparent PVC 0.7mm for class B
  • White lacquered aluminum, 0.6mm thick.
  • Stability with Tª < 55º.
  • Negligible water absorption (0.04 ± 0.01)%.
  • Self-extinguishing.
  • No appreciable lead and phosphorus content (less than 0.01%)
  • Not toxic.

PICTOGRAMS

According to standards:

  • JOINS EN ISO 7010
  • UNE 23033/1

TEXTS

  • According to UNE 23033/1 standard

PHOTOLUMINESCENT PRODUCT

  • Pigment-based compound.
  • Unlimited photo-luminescent charge and discharge cycles

COLOR

Tones according to standard:

  • JOINS EN ISO 7010
  • UNE 23033/1
  • Ink with great adhesion and resistance.
  • It allows great flexibility in the final product.
  • Not self-flaming. Not toxic

FINAL THICKNESS

A class

  • PVC 1.2 m/m (±10%).
  • ALUMINUM 0.8 m/m (±10%)

Class B

  • PVC 0.8 m/m (±10%).
  • ALUMINUM 0.7 m/m (±10%).

REFERENCE

  • Printed on the sign

DIMENSIONS

  • According to UNE 23033/1 standard

COLOR PERCENTAGES

  • According to UNE 23033-1 standard

MAXIMUM VIEWING DISTANCE

  • Printed on the sign.

To calculate the necessary dimensions of a sign, the formula will be applied, up to a maximum distance of 50 m:

S≥ L2 /2000

“S” represents the area of the signal in square meters, and “L” the distance in meters from which the signal can be perceived.

MEASURES

  • CFPAN01LU210210 ............. 210X210 mm

      NORMATIVE

      - UNE 23033/1:2019 (Extinction) - Fire safety. Signaling

      - UNE 23033/2:2019 (Facilities) - Fire safety. Safety signage. Part 2: Signage and identification of fire protection facilities.

      - UNE 23034/1998 (Evacuation) - Fire safety. Safety Signage. Escape routes.

      - UNE 23035-1/2003 - Fire safety. Photoluminescent signage-

      - UNE 23035-4/2003 - NMZ signs periodically pass radioactivity tests that guarantee the non-emission of the signaling element in compliance with the UNE standard. 23035-4.

      - UNE 53127/2002 - Cellular plastics. Determination of the combustion characteristics of specimens in a horizontal position subjected to a small flame.

      - UNE EN ISO 7010: 2012 - Graphic symbols. Colors and safety signs. Registered safety signs (ISO 7010:2011) (Ratified by AENOR in September 2012.)

      - RD 314/2006 (CTE - Technical Building Code)

      - RIPCI 2017 (Extinction) - Fire Protection Installations Regulations.

      - NMZ signs are manufactured with a UNE-EN ISO 9001 certified quality management system

      STORAGE, CLEANING AND CONSERVATION

      The working temperature should not be higher than 45º C. Higher temperatures can deform the support material.

      The optimal storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.

      Cleaning methods; avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.

      The technical building code – Basic fire safety document requires that photoluminescent signage must comply with the UNE 23035 standard.

      In order to preserve the functionality for which the signage systems have been designed, SEKURECO recommends keeping the signs free of dust, dirt or any debris or object that prevents their visibility and identification.

      For cleaning, it is advisable to preferably use soapy solutions, avoiding the use of solvents or abrasive products that could damage the surface of the sign

      Photoluminescent signs must be located in such a way that they receive energy from a natural or artificial light source to ensure their correct operation.

      In accordance with RD 513/2017 (TABLE III), luminescent signaling systems must undergo an annual inspection/review that will be carried out by specialized personnel from the manufacturer, a maintenance company, or by the user personnel or owner of installation.

      Once the useful life of the signals that make up the signaling system has expired, the inspection of said elements will be carried out following the instructions contained in RD 513/2017 and UNE 23035-2

      SIGNAL INSTALLATION

      Check out our blog to learn how to install a sign or poster:https://www.sekureco.eu/blog/76_consejos-de-instalacion-de-senales-de-seguridad.html

      The recommended INSTALLATION HEIGHT ranges between 2 and 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.

      Photoluminescent signs must be located so that they receive energy from a natural or artificial light source to ensure their correct operation.

      The FIXING of the signaling element must be carried out on a firm surface free of dirt.

      The sign may be secured using MECHANICAL ELEMENTS (screws, rivets, etc...) or ADHESIVES (assembly adhesive, glues, silicones...) carefully, avoiding soiling the visible surface or deforming it.

      EVACUATION signage must be installed in such a way that an evacuation can be initiated from any point susceptible to occupation of the premises, so it is recommended to install directional signs on all routes, intersections, stairs, etc. that serve as a route.

      The DOOR signage will be placed on the door lintel with the appropriate label (“EXIT”, “EMERGENCY EXIT”, NO EXIT”, …).

      The signaling of MEANS OF PROTECTION against fire, rescue and/or aid will be carried out on the same elements to be signaled whenever possible.

      ABOUT COFAN

      It is a company that has more than 15 years of experience in the hardware sector, industrial supply, and in the manufacture of safety footwear and other body protection equipment.

      Read moreShow less
      Product Details
      CFPAN01LU210210

      Specific References

      ean13
      8445187181364

      heading

      @COMMENT_AVATAR@

      @CUSTOMER_NAME@

      @AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
      ☆☆☆☆☆ ★★★★★ (@COMMENT_GRADE@)
      @COMMENT_DATE@
      @COMMENT_NO_APPROVE@

      @COMMENT_TITLE@

      @COMMENT_COMMENT@

      @COMMENT_IMAGES@
      @COMMENT_VIDEOS@
      Write a comment
      @COMMENT_AVATAR@

      @CUSTOMER_NAME@

      @AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
      @COMMENT_DATE@
      @COMMENT_NO_APPROVE@

      @COMMENT_COMMENT@

      Reply
      @COMMENT_AVATAR@

      @CUSTOMER_NAME@

      @AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@
      @COMMENT_DATE@
      @COMMENT_NO_APPROVE@

      @COMMENT_COMMENT@

      Reply

      Menu