€1.39 (no TAX)
Evacuation sign Emergency exit Push to Open COFAN
Evacuation sign Emergency exit Push to Open COFAN. The sign is made with a luminescent layer and is available in various sizes
€2.68 (no TAX)
Emergency exit signal Push to open COFAN text and pictogram. It's a high-quality emergency sign and easy to install. The sign is used to signal buildings, auditoriums, businesses and factories to indicate the spaces intended for exit or evacuation, in this case, doors to push open.
The poster is made with a layer of photoluminescent pigment, (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).
The evacuation safety signs are used to indicate and guide people to emergency exits in the event of an event or situation requiring evacuation. These signals are essential to ensure safety and facilitate the rapid and orderly evacuation of a building, auditorium, undertaking or factory.
IDENTIFICATION OF THE PRODUCT
According to UNE 23035/4:
- Manufacturer's name or mark
- Date of manufacture
- Designation (Class A or Class B as appropriate)
According to RIPCI 513:
- Manufacturer's name or mark
MINIMUM LUMINESCENCE VALUES AFTER SALINE
All NMZ signalling shall be subjected to different internal and external light response tests ensuring compliance with the light intensity values referred to in UNE 23035.
CLASS A:
Time of day | Values from UNE 23035-4 (2003) CLASS A |
Value Sekureco CLASS A |
---|---|---|
Luminescence 10 minutes | 210 mcd/m2 | 225 mcd/m2 |
Luminescence 60 minutes | 29 mcd/m2 | 30 mcd/m2 |
Dimming time: | 3,000 minutes | 3,100 minutes |
CLASS B:
Time of day | Values from UNE 23035-4 (2003) CLASS A |
Value Sekureco CLASS A |
---|---|---|
Luminescence 10 minutes | 40 mcd/m2 | 50 mcd/m2 |
Luminescence 60 minutes | 5,6 mcd/m2 | 6,1 mcd/m2 |
Dimming time: | 800 minutes | 900 minutes |
CHARACTERISTICS
PVC SUPPORT MATERIALS
According to UNE 53127:
- White PVC 1 mm for class A and transparent PVC 0,7 mm for class B
- White lacquered aluminum 0.6 mm thick.
- Stability with Ta < 55o.
- Absorption of negligible water (0,04 ± 0,01) %.
- It's self-extinguishing.
- Not containing appreciable amounts of lead and phosphorus (less than 0,01%)
- It's not toxic.
OTHER
According to regulations:
- UNIFIED IN ISO 7010
- OTHER
TEXTS
- According to UNE 23033/1
PHOTOLUMINESCENT PRODUCT
- Composed of pigments.
- Unlimited photoluminescent charge and discharge cycles
COLOUR
Tones by standard:
- UNIFIED IN ISO 7010
- OTHER
- High adhesion and strength ink.
- It allows great flexibility in the final product.
- It's not self-igniting. Not toxic
FINAL THICKNESS
Class A
- PVC 1,2 m/m (± 10%).
- Aluminium 0,8 m/m (± 10%) or more.
Class B
- PVC 0,8 m/m (± 10%) or more.
- Technology" according to the General Technology Note for the "development", "production" or "use" of equipment or "software" specified in 5A001.
REFERENCE
- Printed on the signal
DIMENSIONS
- According to UNE 23033/1
PERCENTAGE OF COLOUR
- According to UNE 23033-1
MAXIMUM DISTANCE OF VISION
- Printed on the signal.
To calculate the necessary dimensions of a signal up to a maximum distance of 50 m, the formula shall be applied:
S≥ L2 /2000
S” represents the surface of the signal in metres squared, and L” the distance in metres from which the signal can be perceived.
MEASURES
Manufacture from materials of any heading
Other, of circular cross-section
Other, of circular cross-section
Other, not further worked than hot-rolled
REGULATORY
- UNE 23034/1998 (evacuation) - fire safety. This is a security signal. Evacuation routes.
- UNE 23035-1/2003 - Safety against fire. Light-emitting signalling-
- UNE 23035-4/2003 - NMZ signals regularly pass radioactivity tests to ensure that the signalling element does not emit in accordance with the UNE standard. 23035 to 4.
- UNE 53127/2002 - Cellular plastics and related products. Determination of the combustion characteristics of test pieces in a horizontal position subjected to a small flame.
- One in ISO 7010:2012 - Graphical symbols and other graphic symbols. Colors and safety signs. Registered safety signals (ISO 7010:2011) (Ratified by AENOR in September 2012)
- RD 314/2006 (CTE - Technical building code)
- RIPCI 2017 (extinction) - Regulation of fire protection facilities.
- NMZ signals are manufactured with UNE-EN ISO 9001 certified quality management system
STORAGE, CLEANING AND PRESERVATION
The working temperature shall not exceed 45 °C. Higher temperatures may deform the support material.
The optimum storage temperature shall be between 15oC and 25oC and a humidity of 10/50%.
Cleaning methods; avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.
The technical building code – Basic fire safety document requires that photoluminescent signalling comply with UNE 23035.
In order to preserve the functionality for which the signalling systems have been designed, SEKURECO recommends that signals be kept free from dust, dirt or any residue or object that prevents their visibility and identification.
For cleaning it is advisable to use soapy solutions preferably, avoiding the use of solvents or abrasive products that may damage the surface of the signal.
Photoluminescent signals shall be so placed that they receive energy from a natural or artificial light source to ensure their correct operation.
In accordance with RD 513/2017 (TABLA III), luminous signalling systems shall be subject to an annual inspection/revision to be carried out by specialised personnel of the manufacturer, a maintenance company or the user or owner of the installation.
At the end of the service life of the signals comprising the signalling system, the inspection of these elements shall be carried out in accordance with the instructions set out in RD 513/2017 and UNE 23035-2
SIGNAL INSTALLATION
Check our blog to learn how to install a sign or sign: https://www.sekureco.eu/blog/76_consejos-de-instalacion-de-senales-de-seguridad.html
The recommended installation height is between 2 and 2.50 metres, always maintaining a separation distance of 0.30 metres from the ceiling.
Photoluminescent signals shall be so placed that they receive energy from a natural or artificial light source to ensure their correct operation.
FIXING of the signalling element shall be carried out on a firm surface free from dirt.
The signal may be secured by means of MECHANICAL ELEMENTS (screwdrivers, rivets, etc.) or ADHESIVES (mounting adhesive, tails, silicones, etc.) carefully, avoiding dirtying the visible surface or deforming it.
EVACUATION signalling must be installed in such a way that an evacuation can be initiated from any point likely to be occupied in the enclosure.
The signage in DOORS shall be placed on the lintel of the door with the appropriate label (“EXIT”, ).EMERGENCY EXIT”, SIN EXIT”, ...).
Means of protection against fire, rescue and/or salvage shall be marked on the same elements to be marked whenever possible.
APPLICATIONS
- Commercial and office buildings
- Hospitals and medical centres
- Schools and universities
- Airports and transport stations
- Hotels
- Shopping centres
- Industrial installations and factories
- Theatre, cinema and entertainment venues
- Restaurants and food establishments.
ON THE HOOD
It is a company with over 15 years' experience in the hardware sector, industrial supply, and in the manufacture of safety footwear and other personal protective equipment.
heading
Ficha Técnica Señal de evacuación Salida de emergencia Empujar para Abrir COFAN skrc download
Declaración de Conformidad El ensayo se realiza según el procedimiento PTICC/65 download
Declaración de Conformidad El ensayo se realiza según el procedimiento PTICC/65 download
@CUSTOMER_NAME@
@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@@COMMENT_TITLE@
@COMMENT_COMMENT@