€25.08 (no TAX)
Oblique arrow evacuation sign with luminescent coating Class A SEKURECO
Oblique arrow evacuation sign with SEKURECO luminescent coating.
This sign is manufactured with ISO 9001 certified quality management system
€6.50 (no TAX)
Oblique arrow evacuation sign with SEKURECO luminescent coating. It is a shigh quality pictogram evacuation sign and easy installation. The sign is used to indicate the evacuation zone in the direction of the arrow in buildings and closed spaces for emergency cases only
Made on a PVC or aluminum sheet with a layer of photoluminescent pigment, (after absorbing light, the product emits it in the dark, so it does not need any electrical source and the product can be charged an indefinite number of times).
Check the available product: SEKURECO Luminescent Down Arrow Evacuation Sign.
PRODUCT IDENTIFICATION
According to UNE 23035/4 standard:
- Name or brand of the manufacturer
- Manufacturing date
- Designation (class A or class B as appropriate)
According to RIPCI 513:
- Name or brand of the manufacturer
MINIMUM LUMINESCENCE VALUES AFTER SALT CHAMBER
All NMZ signage is subjected to different internal and external light response tests that guarantee compliance with the light intensity values contemplated in the UNE 23035 standard.
A CLASS:
Time | Values of UNE 23035-4 (2003) A CLASS |
ValuesSekureco A CLASS |
---|---|---|
Luminescence 10 minutes | 210 mcd/m2 | 225 mcd/m2 |
Luminescence 60 minutes | 29 mcd/m2 | 30 mcd/m2 |
Fade time: | 3,000 minutes | 3,100 minutes |
CLASS B:
Time | Values of UNE 23035-4 (2003) A CLASS |
ValuesSekureco A CLASS |
---|---|---|
Luminescence 10 minutes | 40 mcd/m2 | 50 mcd/m2 |
Luminescence 60 minutes | 5.6 mcd/m2 | 6.1 mcd/m2 |
Fade time: | 800 minutes | 900 minutes |
CHARACTERISTICS
PVC SUPPORT MATERIALS
According to UNE 53127 standard:
- White PVC 1mm for class A and transparent PVC 0.7mm for class B
- White lacquered aluminum, 0.6mm thick.
- Stability with Tª < 55º.
- Negligible water absorption (0.04 ± 0.01)%.
- Self-extinguishing.
- No appreciable lead and phosphorus content (less than 0.01%)
- Not toxic.
PICTOGRAMS
According to standards:
- JOINS EN ISO 7010
- UNE 23033/1
TEXTS
- According to UNE 23033/1 standard
PHOTOLUMINESCENT PRODUCT
- Pigment-based compound.
- Unlimited photo-luminescent charge and discharge cycles
COLOR
Tones according to standard:
- JOINS EN ISO 7010
- UNE 23033/1
- Ink with great adhesion and resistance.
- It allows great flexibility in the final product.
- Not self-flaming. Not toxic
FINAL THICKNESS
A class
- PVC 1.2 m/m (±10%).
- ALUMINUM 0.8 m/m (±10%)
Class B
- PVC 0.8 m/m (±10%).
- ALUMINUM 0.7 m/m (±10%).
REFERENCE
- Printed on the sign
DIMENSIONS
- According to UNE 23033/1 standard
COLOR PERCENTAGES
- According to UNE 23033-1 standard
MAXIMUM VIEWING DISTANCE
- Printed on the sign.
To calculate the necessary dimensions of a sign, the formula will be applied, up to a maximum distance of 50 m:
S≥ L2 /2000
“S” represents the area of the signal in square meters, and “L” the distance in meters from which the signal can be perceived.
MEASURES
CLASS A (PVC 1 mm)
- A0A457...............210X210
- A03457...............420X420
NORMATIVE
- UNE 23033/1:2019 (Extinction) - Fire safety. Signaling
- UNE 23033/2:2019 (Facilities) - Fire safety. Safety signage. Part 2: Signage and identification of fire protection facilities.
- UNE 23034/1998 (Evacuation) - Fire safety. Safety Signage. Escape routes.
- UNE 23035-1/2003 - Fire safety. Photoluminescent signage-
- UNE 23035-4/2003 - NMZ signs periodically pass radioactivity tests that guarantee the non-emission of the signaling element in compliance with the UNE standard. 23035-4.
- UNE 53127/2002 - Cellular plastics. Determination of the combustion characteristics of specimens in a horizontal position subjected to a small flame.
- UNE EN ISO 7010: 2012 - Graphic symbols. Colors and safety signs. Registered safety signs (ISO 7010:2011) (Ratified by AENOR in September 2012.)
- RD 314/2006 (CTE - Technical Building Code)
- RIPCI 2017 (Extinction) - Fire Protection Installations Regulations.
- NMZ signs are manufactured with a UNE-EN ISO 9001 certified quality management system
STORAGE, CLEANING AND CONSERVATION
The working temperature should not be higher than 45º C. Higher temperatures can deform the support material.
The optimal storage temperature will be between 15º C and 25º C; and with a humidity of 10/50%.
Cleaning methods; avoid applying abrasive products. It is recommended to clean them with water and neutral detergents.
The technical building code – Basic fire safety document requires that photoluminescent signage must comply with the UNE 23035 standard.
In order to preserve the functionality for which the signage systems have been designed, SEKURECO recommends keeping the signs free of dust, dirt or any debris or object that prevents their visibility and identification.
For cleaning, it is advisable to preferably use soapy solutions, avoiding the use of solvents or abrasive products that could damage the surface of the sign
Photoluminescent signs must be located in such a way that they receive energy from a natural or artificial light source to ensure their correct operation.
In accordance with RD 513/2017 (TABLE III), luminescent signaling systems must undergo an annual inspection/review that will be carried out by specialized personnel from the manufacturer, a maintenance company, or by the user personnel or owner of installation.
Once the useful life of the signals that make up the signaling system has expired, the inspection of said elements will be carried out following the instructions contained in RD 513/2017 and UNE 23035-2
SIGNAL INSTALLATION
Check out our blog to learn how to install a sign or poster:https://www.sekureco.eu/blog/76_consejos-de-instalacion-de-senales-de-seguridad.html
The recommended INSTALLATION HEIGHT ranges between 2 and 2.50 meters, always maintaining a separation distance of 0.30 meters from the ceiling.
Photoluminescent signs must be located so that they receive energy from a natural or artificial light source to ensure their correct operation.
The FIXING of the signaling element must be carried out on a firm surface free of dirt.
The sign may be secured using MECHANICAL ELEMENTS (screws, rivets, etc...) or ADHESIVES (assembly adhesive, glues, silicones...) carefully, avoiding soiling the visible surface or deforming it.
EVACUATION signage must be installed in such a way that an evacuation can be initiated from any point of occupation in the premises, so it is recommended to install directional signs on all routes, intersections, stairs, etc. that serve as a route.
The DOOR signage will be placed on the door lintel with the appropriate label (“EXIT”, “EMERGENCY EXIT”, NO EXIT”, …).
The signaling of MEANS OF PROTECTION against fire, rescue and/or aid will be carried out on the same elements to be signaled whenever possible.
ABOUT SEKURECO
Experts in workplace safety! We are a young company that emerged in 2016 thanks to the passion of several technicians specialized in prevention and occupational safety and due to the lack of a company specialized in the sector. It offers more than 10 thousand products specialized in labor protection, available to companies and individuals, from the best brands and at the most competitive prices on the market.
@CUSTOMER_NAME@
@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@@COMMENT_TITLE@
@COMMENT_COMMENT@