€414.91 (no TAX)
MaxiFil suction device for welding fumes high capacity KEMPER
MaxiFil suction device for high capacity welding fumes
2 filtration levels, Class E12
€4,536.38 (no TAX)
MaxiFil suction apparatus for high capacity welding fumes with safe filter change. Arm 2 to 7 meters (optional version with hose and version with tube).
MaxiFil filtering equipment combines high filtering capacity with a pollution-free filter change. For applications with medium amounts of smoke and dust, the convenient filtration system works smoothly. The wall mounted model saves space and is ideal for regular on-site use.
Equipment with functionalities similar to One-arm continuous use suction device with self-cleaning filter for welding fumes KEMPER REF: 83100100.
CHARACTERISTICS
- 360° rotary suction bell with regulating valve
- W3/IFA certified
- Automatically start/stop system (optional)
- Lighting of the work area (optional)
- Arms up to 7 m (including peaches)
- Silencer
- Control box
ADDITIONAL EQUIPMENT
- Automatically start/stop system
- Workstation lighting, including ON/OFF on extraction bell
VARIANTS
- Various arm lengths
- Other available supply voltages
SUPPLIER INCLUDES
- Appliance
- Fans
- Silencer
- Control box
- Suction arm with bell
TECHNICAL DATA
Filter
Filtration levels | 2 |
Filtration method | Disposable filter |
Filter surface | approx. 42 m2 |
Type of filter | SafeChangeFilter is not available |
Filter material | Polyester film |
Degree of filtration | > 99,5% |
Filter class | E12 |
Additional filters | Prefilter |
Basic data
Suction power | 1 000 m3/h |
Measurements (A x L x A) | 771 x 776 x 1 other |
Weight | 125 kg |
Engine power | Other |
Power supply voltage | 3 x 400 V / 50 Hz |
Rated current | 3,1 A |
Sound level | 72 dB (A) |
Additional information
IFA certificate | W3 - Tested |
Type of fan | Centrifugal fan |
Angle of suction arms | 1 |
Type of suction arms | Version with hose |
Diameters | other, of circular cross-section |
It's long. Flexible arm | 2 m |
PARTS AND ACCESSORIES
Suction bell - In the case of a vacuum cleaner, the following conditions shall apply:
Hose for suction arm, version with hose - 2,0 m, Ø 150 mm REF: 1140348
Repair and maintenance of machinery
REF: 7905301 is not applicable
Rubber seals - set of 10. THIS REGULATION SHALL BE BINDING IN ITS ENTIRETY AND DIRECTLY APPLICABLE IN ALL MEMBER STATES
FITTINGS
Lighted suction bell for original equipment REF: 79103040
Lighted suction cup REF: 79103045
REF: 1270091 is not applicable
APPLICATIONS
- Flat-rolled products of iron or non-alloy steel
- Moderate amounts of smoke/dust Regular use
BENEFITS
- Safe operation due to direction of rotation recognition
- Less frequent relocation of the suction arm due to the shape of the suction bell
- Increased safety thanks to filter control
- Increased safety thanks to pollution-free filter change
- High profitability thanks to the high capacity and long service life of the filter
FOR WELDING WORK ENVIRONMENTS
In any work environment in which some type of work is carried out welding it is essential that all workers have at their disposal the various Personal Protective Equipment to ensure that they can carry out their activities with the respiratory protection they require in order to avoid the possible occurrence of health problems in workers. In addition, in each installation where welding work is carried out, it is necessary to have the necessary elements in place to provide greater protection Fixed suction device high performance filter smoke welding a great option for industrial use in cases where the emissions are small or moderate.
The Fixed suction filter high-performance smoke welding has a prefilter which helps to extend the life of the main filter. Having two suction arms and integrated control valves allows them to work simultaneously or alternately in two positions, in addition to having a regulated suction power.
Prepared for occasional or frequent use, this fixed two-arm suction apparatus has a 360-degree rotating suction bell with regulating valve, an arm up to 10 meters long, with silencer and control-box, as well as optionally can have an automatic start/stop system and illumination of the work area. It also has additional equipment available such as the on/off system in the suction bell or the activated charcoal equipment kit.
Among the advantages of using the fixed suction apparatus high efficiency smoke filter welding is the convenient change of filter by the maintenance door, great safety thanks to filter control, you can work in two positions simultaneously, less frequent relocation of the suction arm, etc.
This smoke extraction system is a highly effective equipment for respiratory protection in the light of the foregoing, the commission considers that it is appropriate to extend the scope of the directive to cover the following aspects:. It is therefore necessary to take extreme precautions and to ensure that each employee has at his disposal the necessary equipment and elements to perform his work safely.
ABOUT KEMPER
KEMPER is an innovative company and leader in the sector of fume extraction technology produced in metal welding. After more than 40 years of experience in the design of these products, our organization has a deep knowledge of the processes of plants in which metals are worked.
heading
Ficha Técnica Ficha Técnica Aparato de aspiración MaxiFil para humos de soldadura alta capacidad KEMPER download
Manual de Usuario Este manual de servicio es una ayuda esencial para el funcionamiento correcto y seguro del producto. download
Infografía Resumen del Aparato de aspiración MaxiFil para humos de soldadura alta capacidad KEMPER download
@CUSTOMER_NAME@
@AUTHOR_PROFILE@ @COMMENT_ISO_COUNTRY@ @VERIFY_PURCHASE@@COMMENT_TITLE@
@COMMENT_COMMENT@